Potterton boilers are known for their reliability and efficiency, but like any other appliance, they can encounter issues from time to time. One common problem that Potterton boiler owners might face is error code 133. If you’re seeing this error on your boiler, don’t panic – there are a few simple steps you can take to troubleshoot and fix the issue.

Understanding Error Code 133

Error code 133 on a Potterton boiler typically indicates a problem with the ignition or flame sensing. This error can prevent your boiler from firing up properly, leading to a lack of hot water and heating in your home. It’s important to address this issue promptly to avoid any disruptions to your daily routine.

Steps to Fix Error Code 133

Here are the steps you can take to fix error code 133 on your Potterton boiler:

1. Check the Ignition System

The first thing to do is to check the ignition system of your boiler. Make sure that the pilot light is lit and that there are no obstructions blocking the burner. If the pilot light is out, follow the manufacturer’s instructions to relight it. If the pilot light won’t stay lit, you may need to replace the thermocouple.

2. Clean the Flame Sensor

Error code 133 can also be triggered by a dirty or faulty flame sensor. Locate the flame sensor on your boiler – it’s usually a small metal rod near the burner. Carefully remove any dirt or debris on the sensor using a soft brush or cloth. If the sensor is damaged, you may need to replace it.

3. Check the Gas Supply

Another common reason for error code 133 is a lack of gas supply to the boiler. Make sure that the gas valve is fully open and that there are no leaks in the gas line. You can also check the gas pressure using a pressure gauge – if it’s below the recommended level, contact a professional to adjust it.

4. Reset the Boiler

If you’ve checked the ignition system, cleaned the flame sensor, and ensured a proper gas supply but the error code persists, try resetting the boiler. Locate the reset button on your boiler – it’s usually a small red button on the control panel. Press and hold the reset button for a few seconds until you hear a click.

5. Call a Professional

If none of the above steps help resolve error code 133 on your Potterton boiler, it’s time to call a qualified heating engineer. They will have the expertise and tools to diagnose the issue accurately and recommend the best course of action. Trying to fix complex boiler problems yourself can be dangerous and may void your warranty.

Preventing Error Code 133 in the Future

To prevent error code 133 and other boiler issues in the future, it’s essential to schedule regular maintenance checks with a professional. A qualified engineer can inspect your boiler, clean the components, and make any necessary repairs to keep it running smoothly. Additionally, make sure to follow the manufacturer’s guidelines for proper use and maintenance of your Potterton boiler.
In conclusion, error code 133 on a Potterton boiler is a common issue that can be resolved with some basic troubleshooting steps. By checking the ignition system, cleaning the flame sensor, and ensuring a proper gas supply, you can address this error and restore your boiler’s functionality. If the problem persists, don’t hesitate to seek help from a professional heating engineer to avoid further complications. Remember, regular maintenance is key to keeping your boiler in top condition and preventing future errors.